CV Series Switches for 115 or 115/230 Voltage (VAC) Dual Voltage Capacitor Start Motor
SINPAC® Solid State Switches
Basic Operation
Capacitor start motor require a method to extract speed data from the voltage across the motor start winding. By comparing the start winding RPM-sensitive voltage with the main AC input voltage (which serves as a reference voltage), the switch determines when the start circuit should be energized. The electronic switch interrupts the start circuit current after the motor has accelerated to the cut out speed, and reconnects the start circuit whenever the motor speed has fallen to cut in speed (usually about 50 % of synchronous motor speed).
Capacitor start motor require a method to extract speed data from the voltage across the motor start winding. By comparing the start winding RPM-sensitive voltage with the main AC input voltage (which serves as a reference voltage), the switch determines when the start circuit should be energized. The electronic switch interrupts the start circuit current after the motor has accelerated to the cut out speed, and reconnects the start circuit whenever the motor speed has fallen to cut in speed (usually about 50 % of synchronous motor speed).
Item # |
Typical Maximum Motor |
Typical
|
Typical
|
Switch Rating
|
Typical Cut Out Voltage |
List Price |
---|---|---|---|---|---|---|
CV-16-130-OBSOLETE - REPLACEMENT CV-40-130 CV-16-130-OBSOLETE - REPLACEMENT CV-40-130/Asset/a1150.jpg | Typical Maximum Motor N/A 1/2 hp |
Typical Full Load Motor Current Rating (115 Volts) N/A 8 A |
Typical Full Load Motor Current Rating (115/230 Volts) N/A 8/4 A |
Switch Rating Permissible Max Start Winding Current N/A 16 A |
Typical Cut Out Voltage N/A 130 V | $0.00 |
CV-16-147-OBSOLETE-REPLACEMENT CV-40-147 CV-16-147-OBSOLETE-REPLACEMENT CV-40-147/Asset/a1150.jpg | Typical Maximum Motor N/A 1/2 hp |
Typical Full Load Motor Current Rating (115 Volts) N/A 8 A |
Typical Full Load Motor Current Rating (115/230 Volts) N/A 8/4 A |
Switch Rating Permissible Max Start Winding Current N/A 16 A |
Typical Cut Out Voltage N/A 147 V | $0.00 |
CV-16-165 - OBSOLETE-REPLACEMENT CV-40-165 CV-16-165 - OBSOLETE-REPLACEMENT CV-40-165/Asset/a1150.jpg | Typical Maximum Motor N/A 1/2 hp |
Typical Full Load Motor Current Rating (115 Volts) N/A 8 A |
Typical Full Load Motor Current Rating (115/230 Volts) N/A 8/4 A |
Switch Rating Permissible Max Start Winding Current N/A 16 A |
Typical Cut Out Voltage N/A 165 V | $0.00 |
CV-25-130 - OBSOLETE - REPLACEMENT CV-40-130 CV-25-130 - OBSOLETE - REPLACEMENT CV-40-130/Asset/a1150.jpg | Typical Maximum Motor N/A 1 hp |
Typical Full Load Motor Current Rating (115 Volts) N/A 12 A |
Typical Full Load Motor Current Rating (115/230 Volts) N/A 12/6 A |
Switch Rating Permissible Max Start Winding Current N/A 25 A |
Typical Cut Out Voltage N/A 130 V | $0.00 |
CV-25-147 - OBSOLETE-REPLACEMENT CV-40-147 CV-25-147 - OBSOLETE-REPLACEMENT CV-40-147/Asset/a1150.jpg | Typical Maximum Motor N/A 1 hp |
Typical Full Load Motor Current Rating (115 Volts) N/A 12 A |
Typical Full Load Motor Current Rating (115/230 Volts) N/A 12/6 A |
Switch Rating Permissible Max Start Winding Current N/A 25 A |
Typical Cut Out Voltage N/A 147 V | $0.00 |
CV-25-165 - OBSOLETE-REPLACEMENT CV-40-165 CV-25-165 - OBSOLETE-REPLACEMENT CV-40-165/Asset/a1150.jpg | Typical Maximum Motor N/A 1 hp |
Typical Full Load Motor Current Rating (115 Volts) N/A 12 A |
Typical Full Load Motor Current Rating (115/230 Volts) N/A 12/6 A |
Switch Rating Permissible Max Start Winding Current N/A 25 A |
Typical Cut Out Voltage N/A 165 V | $0.00 |
CV-40-130 CV-40-130/Asset/a1150.jpg | Typical Maximum Motor N/A 2 hp |
Typical Full Load Motor Current Rating (115 Volts) N/A 20 A |
Typical Full Load Motor Current Rating (115/230 Volts) N/A 20/10 A |
Switch Rating Permissible Max Start Winding Current N/A 40 A |
Typical Cut Out Voltage N/A 130 V | $132.83 |
CV-40-147 CV-40-147/Asset/a1150.jpg | Typical Maximum Motor N/A 2 hp |
Typical Full Load Motor Current Rating (115 Volts) N/A 20 A |
Typical Full Load Motor Current Rating (115/230 Volts) N/A 20/10 A |
Switch Rating Permissible Max Start Winding Current N/A 40 A |
Typical Cut Out Voltage N/A 147 V | $132.83 |
CV-40-165 - OBSOLETE-REPLACEMENT CV-50-165 CV-40-165 - OBSOLETE-REPLACEMENT CV-50-165/Asset/a1150.jpg | Typical Maximum Motor N/A 2 hp |
Typical Full Load Motor Current Rating (115 Volts) N/A 20 A |
Typical Full Load Motor Current Rating (115/230 Volts) N/A 20/10 A |
Switch Rating Permissible Max Start Winding Current N/A 40 A |
Typical Cut Out Voltage N/A 165 V | $0.00 |
CV-50-130 - OBSOLETE CV-50-130 - OBSOLETE/Asset/a1150.jpg | Typical Maximum Motor N/A 3 hp |
Typical Full Load Motor Current Rating (115 Volts) N/A 25 A |
Typical Full Load Motor Current Rating (115/230 Volts) N/A 25/12.5 A |
Switch Rating Permissible Max Start Winding Current N/A 50 A |
Typical Cut Out Voltage N/A 130 V | $0.00 |
CV-50-147 OBSOLETE CV-50-147 OBSOLETE/Asset/a1150.jpg | Typical Maximum Motor N/A 3 hp |
Typical Full Load Motor Current Rating (115 Volts) N/A 25 A |
Typical Full Load Motor Current Rating (115/230 Volts) N/A 25/12.5 A |
Switch Rating Permissible Max Start Winding Current N/A 50 A |
Typical Cut Out Voltage N/A 147 V | $0.00 |
CV-50-165 CV-50-165/Asset/a1150.jpg | Typical Maximum Motor N/A 3 hp |
Typical Full Load Motor Current Rating (115 Volts) N/A 25 A |
Typical Full Load Motor Current Rating (115/230 Volts) N/A 25/12.5 A |
Switch Rating Permissible Max Start Winding Current N/A 50 A |
Typical Cut Out Voltage N/A 165 V | $151.15 |